Katalox Light System

7" x 44" Requires Backwash Only. For flow rates up to 4 G.P.M. Other sizes are available. Comes complete with Fleck 5600 Valve Controller, 3/4" By-Pass, Tank and Media

Retail Price : $1,119.58
Our Low Price : $829.32


No Chemical Dependency !

Real installations from different part of the world have been reported to remove unchallenged amounts of iron. In a few extreme cases multi-stage Katalox-Light filtration systems have been used without the use of any chemicals to remove iron with inlet concentration of as high as 60 - 100 mg/L ppm .

These astounding findings are being further investigated to find the co-rrelations between removal limit and underlying ORP, pH and other possible governing characteristics.

Eliminate iron, sulfur hydrogen sulfide , Manganeese and particulates. 

Chemcical Free. Katalox only needs to be back washed and average of every other day. Works well in pH ranges of 5.8 and above. 

Media Description: High content 10% gamma Manganese dioxide MnO2 coated ZEOSORB 

Katalox-Light® Removal methods:
1. Mechanical Filtration fine particles, TSS, Turbidity etc.
2. Catalytic precipitation and sorption Fe, Mn, Cu, Pb etc.
3. Adsorbtion flocculant formation and adsorption of As, Heavy Metals, Radionuclides

 
Katalox Light®
BIRM
Greensand Plus
ManOX
Contains Silica, Quartz
No
Yes
Yes
No
Conatins Silica, Tripoli
No
Yes
Yes
No
Carcinogen in humans
No
Yes
Yes
No
Treats Iron
at pH 6 - 9
only above 6.8
only above 6.8
above 6.8
Treats Manganese at pH 7
Yes
No
Yes
Yes
Treats Hydrogen Sulfide
Yes, High Capacity*
No
Limited
Limited
Removes Arsenic III & V
Yes**
No
Limited
?
Removes Uranium and Radium
Yes
No
No
No
Removes Lead & Copper
Yes***
No
No
No
Bulk Density SI
1060 kg/m³
800 kg/m³
1425 kg/m³
2400 kg/m³
US
66 lb/ft³
50 lb/ft³
89 lb/ft³
150 lb/ft³
Operational pH range
5.8 - 10.5
> 6.8
6.5 - 8.5
6.5 - 9.0
Tolerance to Oxidizing agents
High tolerance
Only air
medium
medium
Fine Sediment Filtration
High performance.
Filtration up to 2-3 micron
Not a Filter
No
No
 

 

Click for Media Specsheet


Advanced Applications:

 
• Fracking: Reducing radionuclide waste in fracking wastewater
• Industrial waste water
• Cooling tower re-circulation: dramatically reducing the blow-down water and using part of it in re-circulation process
• Reverse Osmosis Pre-treatment: Increasing the membrane life-span 3-4 times more
• Cyanide removal
• Removal of Arsenic by the method of co-precipitation see detail
• Radionuclide removal Radium, Uranium :

As a side note : If you have both Iron of at least 1 p.p.m. Katalog will remove up to 50 p.p.b. of Arsenic. The arsenic is removed using the Iron Oxide that binds to the media. 



Related Categories

  • Miscellaneous Products
  • 56AFB-7-KL - Katalox Light System

    All Images are representative and may or may not be of actual product.

    Tags : BARNSTEAD WATER | 56AFB-7-KL | - | KATALOX | LIGHT | SYSTEM

    BARNSTEAD-WATER.COM content (C)2009-2024 APS Water Services Corporation - All rights reserved
    Website Software - Multi-Website Content Manager - Wilson Web Engineering (C)2012-2024

    Micro-Website is a trademark of Wilson Web Engineering

    56afb-7-kl - katalox light system
    barnstead-water.com micro-website™
    4/19/2024
    7:03:25 AM

    56afb-7-kl - katalox light system | barnstead-water.com
    Google Apps

    Barnstead Filters and Parts


    Other APS Web Properties
    Barnstead-Water.com lab-Water-filters.com lab-water System.com LabFilter.com Millipore-alternative.com Durastill Water Distillers Ahlstrom-Filters.com