68 results found.
MODEL 5600 & 5600 ECONOMINDER® SERVICE MANUAL IMPORTANT: FILL IN PERTINENT INFORMATION ON PAGE 2 FOR FUTURE REFERENCE. MODEL 5600 & 5600 ECONOMINDER® JOB SPECIFICATION SHEET JOB NO. __________________________________________________________ *MODEL NO. ______________________________________________________ WATER TEST ______________________________________________________ CAPACITY PER UNIT_____________ MAX. ___________PER REGENERATION MINERAL TANK SIZE DIA.________ HEIGHT_________ BRINE TANK SIZE & SALT SETTING PER REGENERATION: _______________________________________________________________...
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE™ LF OPERATION MANUAL AND PARTS LIST SERIES 1052 LT1052X2 9/8/97 1 IMPORTANT INFORMATION THIS MANUAL CONTAINS IMPORTANT OPERATING AND SAFETY INFORMATION. YOU MUST CAREFULLY READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL PRIOR TO THE USE OF THIS EQUIPMENT. WATER PURIFICATION TECHNOLOGY EMPLOYS ONE OR MORE OF THE FOLLOWING: CHEMICALS, ELECTRICAL DEVICES, MERCURY VAPOR LAMPS, STEAM AND HEATED VESSELS. CARE SHOULD BE TAKEN WHEN INSTALLING, OPERATING OR SERVICING BARNSTEAD PRODUCTS. THE SPECIFIC SAFETY NOTES PERTINENT TO THIS BARNSTEAD PRODUCT ARE LISTE...
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE™ LF OPERATION MANUAL AND PARTS LIST SERIES 1052 LT1052X2 9/8/97 1 IMPORTANT INFORMATION THIS MANUAL CONTAINS IMPORTANT OPERATING AND SAFETY INFORMATION. YOU MUST CAREFULLY READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL PRIOR TO THE USE OF THIS EQUIPMENT. WATER PURIFICATION TECHNOLOGY EMPLOYS ONE OR MORE OF THE FOLLOWING: CHEMICALS, ELECTRICAL DEVICES, MERCURY VAPOR LAMPS, STEAM AND HEATED VESSELS. CARE SHOULD BE TAKEN WHEN INSTALLING, OPERATING OR SERVICING BARNSTEAD PRODUCTS. THE SPECIFIC SAFETY NOTES PERTINENT TO THIS BARNSTEAD PRODUCT ARE LISTE...
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE® RF OPERATION MANUAL AND PARTS LIST SERIES 1051 MODEL D7032 MODEL D7031 MODEL D7033 MODEL D7033-33 100 VOLTS 120 VOLTS 240 VOLTS 230 VOLTS LT1051X1 8/22/97 1 TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION ................................................................................................................................3 ALERT BOXES ............................................................................................................................................3 WARNINGS ...................................................
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE® RF OPERATION MANUAL AND PARTS LIST SERIES 1051 MODEL D7032 MODEL D7031 MODEL D7033 MODEL D7033-33 100 VOLTS 120 VOLTS 240 VOLTS 230 VOLTS LT1051X1 8/22/97 1 TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION ................................................................................................................................3 ALERT BOXES ............................................................................................................................................3 WARNINGS ...................................................
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE™ LF OPERATION MANUAL AND PARTS LIST SERIES 1052 LT1052X2 9/8/97 1 IMPORTANT INFORMATION THIS MANUAL CONTAINS IMPORTANT OPERATING AND SAFETY INFORMATION. YOU MUST CAREFULLY READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL PRIOR TO THE USE OF THIS EQUIPMENT. WATER PURIFICATION TECHNOLOGY EMPLOYS ONE OR MORE OF THE FOLLOWING: CHEMICALS, ELECTRICAL DEVICES, MERCURY VAPOR LAMPS, STEAM AND HEATED VESSELS. CARE SHOULD BE TAKEN WHEN INSTALLING, OPERATING OR SERVICING BARNSTEAD PRODUCTS. THE SPECIFIC SAFETY NOTES PERTINENT TO THIS BARNSTEAD PRODUCT ARE LISTE...
BANTAM DEIONIZER TYPE D0800, SERIES 494 OPERATING MANUAL AND PARTS LIST 60119 REV. 0 _________________________________________________________________________________ PART OF THERMO FISHER SCIENTIFIC PREFACE MODELS COVERED IN THIS MANUAL MODEL NUMBER VOLTAGE D0800 (7107) 120V D0805 (7108) 240V MANUAL NUMBER 60119 (7007107) 0 -- 6/4/10 TRANSFER TO MARIETTA (WAS 60119 3/12/08) CCS REV ECR/ECN DATE DESCRIPTION BY THERMO SCIENTIFIC DEIONIZER I PREFACE IMPORTANT READ THIS INSTRUCTION MANUAL. FAILURE TO READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL MAY RESULT IN DAMAGE TO THE UNIT,...
BARNSTEAD|THERMOLYNE CORPORATION EASYPURE® RF OPERATION MANUAL AND PARTS LIST SERIES 1051 MODEL D7032 MODEL D7031 MODEL D7033 MODEL D7033-33 100 VOLTS 120 VOLTS 240 VOLTS 230 VOLTS LT1051X1 8/22/97 1 TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION ................................................................................................................................3 ALERT BOXES ............................................................................................................................................3 WARNINGS ...................................................
MODEL 2510 CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS BACK VALVE MATERIAL FIBER REINFORCED POLYMER W INLET/OUTLET 3/4, 1 OR 1-1/4 CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 19 GPM PEAK (25 PSI DROP) 24 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 17 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES FULLY ADJUSTABLE 5-CYCLE TOP MOUNT CONTROL DELIVERS TIME AVAILABLE ELECTROMECHANICAL: 164 MINUTES CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW SE: 0 - 99 MINUTES RINSE, RAPID RINSE, BRINE REF...
MODEL 1500 .75 RESIDENTIAL CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS MANUAL CONTROL OPTION VALVE MATERIAL LEAD-FREE BRASS* W INLET/OUTLET 3/4 NPTF CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 17 GPM PEAK (25 PSI DROP) 22 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 14 GPM REGENERATION DOWNFLOW/UPFLOW DOWNFLOW ONLY PRODUCT FEATURES ADJUSTABLE CYCLES YES TIME AVAILABLE 164 MINUTES FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW RINSE, RAPID RINSE, METER INFORMATION BRINE REFILL AND DOWN...